Predictive repair that cuts downtime by days

Prediction Report

Ticket #JOB-5 · July 11, 2026 · Predicted
Submitted inputs · July 11, 2026 · 7:33 PM
Symptoms
Does it run at all?: trips on start
What does the motor drive?: pump
What changed?: restart after outage
Can you turn the shaft by hand, uncoupled?: unknown
Drive & installation
Coupling: belt
Isolated/locked out: no
Mounting: vertical
Environment: clean dry
Times rewound: Gemma
Shaft grounding/insulated bearing: yes
Tests
Surge: pass
Ground/continuity: fail
Vibration: 1x_speed_imbalance
Notes
Hi, I was just looking at rotoragent.ai and wanted to ask: are you looking to scale your Instagram presence right now? We help brands like yours add 300+ targeted Instagram followers every month using manual outreach and ads. We can grow your existing page or even build a brand-new profile from scratch for you if you'd prefer a fresh start. Would you like me to send over some more info on how it works? Thanks for your time, Gemma
⚠ UnpredictableConfidence 85/100 · High
Executive summary
Motor trips on start at power restoration with a failed ground/continuity test — treat as a ground-fault until proven otherwise. DO NOT energize: the unit is not locked out. First action is LOTO, then a megger insulation-to-ground test to localize the fault.
Est. cost · internal
$1,700
Labor
14 hrs
Turnaround
5 business days
Repair vs. replace
Repair (size unknown — confirm HP)
Likely failure mode
Mediumground-wall insulation failure
MediumMoisture/contamination surface fault after the outage caused a recoverable ground reading, not degraded ground-wall insulation
Lowground fault in cabling/connections, not motor
Required repairs
• Rewind or repair stator ground-wall insulation, pending teardown confirmation
• Clean, dip and bake windings if fault proves to be moisture/contamination, pending PI/IR results
• Dynamic balance rotor / correct belt-drive imbalance, pending vibration re-check
Material staging
Magnet wire (copper, rewind) ×lot · ~4d lead
98% likelyorder before teardown
Insulation kit — slot liners, wedges, phase paper ×1 set · ~3d lead
98% likelyorder before teardown
DE bearing ×1 · ~2d lead
95% likelyorder before teardown
ODE bearing ×1 · ~2d lead
95% likelyorder before teardown
Shaft / bearing seals ×set · ~1d lead
90% likelycheck stock
Varnish / resin (VPI or dip-and-bake) ×as req
95% likelycheck stock
Lead wire & sleeving ×as req · ~1d lead
80% likelycheck stock
Labor — 14 hrs total
Teardown & clean
2.1 h
Strip & rewind
6.3 h
Fit new bearings
1.1 h
VPI / dip & bake
1.7 h
Reassemble
1.7 h
Test & balance
1.1 h
Reinstall & coverage
• Reinstall & laser alignment on site — field service, quoted separately
• 12-month workmanship warranty — carried in the estimate
• Preventive maintenance plan — optional add-on
Sharpen estimate
Add evidence to tighten the estimate and raise confidence:
Insulation resistance + polarization index (IEEE 43) — separates a full rewind from a cleanable/bakeable winding — the biggest cost swing
Winding-resistance balance — flags opens / bad connections vs. a sound winding
Photo of the winding (burn pattern) — burn pattern often fixes the mode and the rewind extent
insulation resistance value + polarization index — reduces remaining uncertainty in the scope
Confirmed outcome
Reasoning
ground-wall insulation failure — tests: ground/continuity fail; questions: trips on start after outage restart
Moisture/contamination surface fault after the outage caused a recoverable ground reading, not degraded ground-wall insulation — QUESTION ANSWERS: fault appeared on restart after outage, consistent with condensation/moisture ingress during downtime; TEST INPUTS: surge test pass indicates turn-to-turn and winding dielectric intact, pointing to a surface leakage path rather than bulk insulation breakdown
ground fault in cabling/connections, not motor — belt-coupled + external supply path — fault may live upstream of motor
mechanical imbalance (secondary) — tests: vibration dominant 1x_speed_imbalance
No nameplate, no insulation value, and no identification of the tripping device cap overall confidence; the ground-fault call rests on a single pass/fail test channel without a measured IR to grade it.